Records |
Links |
|
Author |
Coulton, R.; Bullen, C.; Hallett, C. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
The design and optimisation of active mine water treatment plants |
Type |
Journal Article |
|
Year |
2003 |
Publication |
Land Contam. Reclam. |
Abbreviated Journal |
|
|
|
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
11 |
Issue |
2 |
Pages |
273-280 |
|
|
Keywords |
sludge mine water treatment mine water active treatment precipitation iron manganese high density sludge sulphide Groundwater problems and environmental effects Pollution and waste management non radioactive manganese sulfide pollutant removal iron water treatment mine drainage |
|
|
Abstract |
This paper provides a 'state of the art' overview of active mine water treatment. The paper discusses the process and reagent selection options commonly available to the designer of an active mine water treatment plant. Comparisons are made between each of these options, based on technical and financial criteria. The various different treatment technologies available are reviewed and comparisons made between conventional precipitation (using hydroxides, sulphides and carbonates), high density sludge processes and super-saturation precipitation. The selection of reagents (quick lime, slaked lime, sodium hydroxide, sodium carbonate, magnesium hydroxide, and proprietary chemicals) is considered and a comparison made on the basis of reagent cost, ease of use, final effluent quality and sludge settling criteria. The choice of oxidising agent (air, pure oxygen, peroxide, etc.) for conversion of ferrous to ferric iron is also considered. Whole life costs comparisons (capital, operational and decommissioning) are made between conventional hydroxide precipitation and the high density sludge process, based on the actual treatment requirements for four different mine waters. |
|
|
Address |
R. Coulton, Unipure Europe Ltd., Wonastow Road, Monmouth NP25 5JA, United Kingdom |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0967-0513 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
The design and optimisation of active mine water treatment plants; 2530436; United-Kingdom 4; Geobase |
Approved |
no |
|
|
Call Number |
CBU @ c.wolke @ 17513 |
Serial |
59 |
|
Permanent link to this record |
|
|
|
|
Author |
Sastri, V.S. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Performance Of Some Reverse-Osmosis Membranes And Their Application In Separation Of Metals In Acid Mine-Water |
Type |
Journal Article |
|
Year |
1976 |
Publication |
Separation Science |
Abbreviated Journal |
|
|
|
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
11 |
Issue |
2 |
Pages |
133-146 |
|
|
Keywords |
mine water treatment |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Performance Of Some Reverse-Osmosis Membranes And Their Application In Separation Of Metals In Acid Mine-Water; Wos:A1976bt15300002; Times Cited: 10; ISI Web of Science |
Approved |
no |
|
|
Call Number |
CBU @ c.wolke @ 9247 |
Serial |
98 |
|
Permanent link to this record |
|
|
|
|
Author |
Tarutis Jr, W.J.; Stark, L.R.; Williams, F.M. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Sizing and performance estimation of coal mine drainage wetlands |
Type |
Journal Article |
|
Year |
1999 |
Publication |
Ecological Engineering |
Abbreviated Journal |
|
|
|
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
12 |
Issue |
3-4 |
Pages |
353-372 |
|
|
Keywords |
mine water treatment coal mine drainage constructed wetlands efficiency first-order removal loading rate removal kinetics sizing zero-order removal constructed wetlands water-quality iron kinetics removal model phosphorus retention mechanism design Wetlands and estuaries geographical abstracts: physical geography hydrology (71 6 8) acid mine drainage effluent performance assessment remediation wetland management |
|
|
Abstract |
The effectiveness of wetland treatment of acid mine drainage (AMD) was assessed using three measures of performance: treatment efficiency, area-adjusted removal, and first-order removal. Mathematical relationships between these measures were derived from simple kinetic equations. Area-adjusted removal is independent of pollutant concentration (zero-order reaction kinetics), while first-order removal is dependent on concentration. Treatment efficiency is linearly related to area-adjusted removal and exponentially related to first-order removal at constant hydraulic loading rates (flow/area). Examination of previously published data from 35 natural AMD wetlands revealed that statistically significant correlations exist between several of the performance measures for both iron and manganese removal, but these correlations are potentially spurious because these measures are derived from, and are mathematical rearrangements of, the same operating data. The use of treatment efficiency as a measure of performance between wetlands is not recommended because it is a relative measure that does not account for influent concentration differences. Area-adjusted removal accounts for mass loading effects, but it fails to separate the flow and concentration components, which is necessary if removal is first-order. Available empirical evidence suggests that AMD pollutant removal is better described by first-order kinetics. If removal is first-order, the use of area-adjusted rates for determining the wetland area required for treating relatively low pollutant concentrations will result in undersized wetlands. The effects of concentration and flow rate on wetland area predictions for constant influent loading rates also depend on the kinetics of pollutant removal. If removal is zero-order, the wetland area required to treat a discharge to meet some target effluent concentration is a decreasing linear function of influent concentration (and an inverse function of flow rate). However, if removal is first-order, the required wetland area is a non-linear function of the relative influent concentration. Further research is needed for developing accurate first-order rate constants as a function of influent water chemistry and ecosystem characteristics in order to successfully apply the first-order removal model to the design of more effective AMD wetland treatment systems. |
|
|
Address |
W.J. Tarutis Jr., Department of Natural Science, Lackawanna Junior College, 501 Vine Street, Scranton, PA 18509, United States |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0925-8574 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Feb.; Sizing and performance estimation of coal mine drainage wetlands; 0427766; Netherlands 46; file:///C:/Dokumente%20und%20Einstellungen/Stefan/Eigene%20Dateien/Artikel/10596.pdf; Geobase |
Approved |
no |
|
|
Call Number |
CBU @ c.wolke @ 10596 |
Serial |
25 |
|
Permanent link to this record |
|
|
|
|
Author |
Driussi, C. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Technological options for waste minimisation in the mining industry |
Type |
Journal Article |
|
Year |
2006 |
Publication |
J. Cleaner Prod. |
Abbreviated Journal |
|
|
|
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
14 |
Issue |
8 |
Pages |
682-688 |
|
|
Keywords |
mine water treatment |
|
|
Abstract |
Just as the application of technology in mining processes can cause pollution, it can also be harnessed to minimise, and sometimes eliminate, mine-related contaminants. Waste minimisation can be achieved through decreased waste production, waste collection, waste recycling, and the neutralisation of pollutants into detoxified forms. This article reviews examples of how technology can be used to minimise air, water, land and noise pollution in the mining industry. (c) 2005 Elsevier Ltd. All rights reserved. |
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Technological options for waste minimisation in the mining industry; Wos:000237749600002; Times Cited: 1; ISI Web of Science |
Approved |
no |
|
|
Call Number |
CBU @ c.wolke @ 16924 |
Serial |
110 |
|
Permanent link to this record |
|
|
|
|
Author |
Bosman, D.J. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Lime Treatment Of Acid-Mine Water And Associated Solids Liquid Separation |
Type |
Journal Article |
|
Year |
1983 |
Publication |
Water Sci. Technol. |
Abbreviated Journal |
|
|
|
Volume ![sorted by Volume (numeric) field, ascending order (up)](img/sort_asc.gif) |
15 |
Issue |
2 |
Pages |
71-84 |
|
|
Keywords |
mine water treatment |
|
|
Abstract |
|
|
|
Address |
|
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
|
Place of Publication |
|
Editor |
|
|
|
Language |
|
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
|
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
Lime Treatment Of Acid-Mine Water And Associated Solids Liquid Separation; Wos:A1983qg97300005; Times Cited: 7; ISI Web of Science |
Approved |
no |
|
|
Call Number |
CBU @ c.wolke @ 14794 |
Serial |
95 |
|
Permanent link to this record |