|
Karathanasis, A. D., & Barton, C. D. (1999). The revival of a failed constructed wetland treating a high Fe load AMD. In K. S. Sajwan, A. K. Alva, & R. F. Keefer (Eds.), Proceedings; biogeochemistry of trace elements in coal and coal combustion byproducts. New York: Kluwer Academic/Plenum Publishers.
|
|
|
Wolkersdorfer, C. (2002). Mine water tracing. Geological Society Special Publication, -(198), 47–60.
Abstract: This paper describes how tracer tests can be used in flooded underground mines to evaluate the hydrodynamic conditions or reliability of dams. Mine water tracer tests are conducted in order to evaluate the flow paths of seepage water, connections from the surface to the mine, and to support remediation plans for abandoned and flooded underground mines. There are only a few descriptions of successful tracer tests in the literature, and experience with mine water tracing is limited. Potential tracers are restricted due to the complicated chemical composition or low pH mine waters. A new injection and sampling method ('LydiA'-technique) overcomes some of the problems in mine water tracing. A successful tracer test from the Harz Mountains in Germany with Lycopodium clavatum, microspheres and sodium chloride is described, and the results of 29 mine water tracer tests indicate mean flow velocities of between 0.3 and 1.7 m min-1.
|
|
|
Stewart, D., Norman, T., Cordery-Cotter, S., Kleiner, R., Sweeney, E., & Nelson, J. D. (1997). Utilization of a ceramic membrane for acid mine drainage treatment. Tailings and Mine Waste '97, , 453–460.
Abstract: BASX Systems LLC has developed a treatment system based on ceramic membranes for the removal of heavy metals from an acid mine drainage stream. This stream also contained volatile organic compounds that were required to be removed prior to discharge to a Colorado mountain stream. The removal of heavy metals was greater than 99% in most cases. A decrease of 30% in chemicals required for treatment and a reduction by more than 75% in labor over a competing technology were achieved. These decreases were obtained for operating temperatures of less than 5 degrees C. This system of ceramic microfiltration is capable of treating many different types of acid mine waste streams for heavy metals removal.
|
|
|
Franchet, J. (1995). An example of sulphate removal by nanofiltration – The treatment of iron ore mine water in Lorraine. Membranes in Drinking Water Production, , 27–31.
|
|
|
Blowes, D. W. (1995). Treatment of mine drainage water using in situ permeable reactive walls. Sudbury '95 – Mining and the Environment, Conference Proceedings, Vols 1-3, , 979–987.
|
|