Isaacson, A. E., & Jeffers, T. H. (1995). Acid mine drainage remediation through applied water treatment systems Pollution prevention for process engineering. In P. E. Richardson, B. J. Scheiner, & Jr. F. Lanzetta (Eds.),. New York: Engineering Foundation.
|
Hause, D. R., & Willison, L. R. (1986). Deep Mine Abandonment Sealing and Underground Treatment to Prelude Acid Mine Drainage.
Abstract: Beth Energy's Mine 105W is located in Barbour County, West Virginia, near Buckhannon. The mine was opened by drifts updip into the Pittsburgh Seam in 1971 and operated until June, 1982. Most of the water which enters Mine 105W percolates down from previously mined areas in the Redstone Seam, Mine 101, which generally lies 38 feet above the Pittsburgh Seam. The quality of this water is good as it enters Mine 105W. While operating, the Mine 105W water was segregated by pumping. The bulk of the water was collected in sumps near the main area of infiltration from the Redstone Seam and was pumped to Gnatty Creek Portal where, because of the quality, it was minimally treated and discharged. The remainder of the water flowed to the original West Portal where it was occasionally treated with lime.
|
Gerth, A., & Kießig, G. (2001). (A. Leeson, Ed.). Phytoremediation, wetlands and sediments. (6)5: Battelle Press.
Abstract: Treatment of radioactively-contaminated and metal-laden mine waters and of seepage fiom tailings ponds and waste rock piles is among the key issues facing WISMUT GmbH in their task to remediate the legacy of uranium mining and processing in the Free States of saxony and rhuringia, Federal Republic of Germany. Generally, contaminant loads of feed waters wn aimnisn over time. At a certain level of costs for the removal of one contaminant unit, continued operation of conventional water treatment plants can hardly be justified any longer. As treatment is still required for water protection, there is an urgent need for-the development and implementation of more cost efficient technologies. WISMUT GmbH and BioPlanta GmbH have studied the suitability of helophye species for contaminant removal from mine waters. In a fust step, original waters were used for an in vitro bioassay. The test results allowed for the determination of the effects of biotic and abiotic factors on helophy'tes'tolerancer ange, growth, and uptake capability of radionuclides and metals. Test series were carried out using Phiagmites australis, Carex disticha, Typha latifolia, and Juncus effusus. Relevant cont-aminant components of the mine waters under investigation included uraniunl iron, arsenic, manganese, nickel, and copper. Investigations led to a number of recommendations conceming plant selection for specific water treatment needs. In a second step, based on these results, a constructed wetland was built in l99g as a pilot plant for the treatment of flood waters liom the pöhla-Tellerhäuser mine and went on-line. Relevant constituents of the neutral flood waters include radium, iron, and arsenic. This wetland specifically uses both physico-chemical and microbiological processes as well as contaminant accumulation by helophytes to achieve the treatment objectives. with the pilot plant in operation for three years now, average removal rates achieved are 95 Yo for kon, 86 yo for arsenic, and 75 % for raäium. WISMUT GmbH intends to put a number of other projects of passive/biological mine water treatment into operation before the end of 2001_
|
Ettner, D. C. (2007). (R. Cidu, & F. Frau, Eds.). Water in Mining Environments. Cagliari: Mako Edizioni.
Abstract: Previous mining history in Norway has resulted in ongoing release of acid mine drainage. Preservation of the historical sites in mining areas does not allow for remediation technologies that result in significant alteration of the historical landscape. Therefore, alternative remediation techniques such as passive mine water treatment have been tested. The climate in Norway varies from mild coastal climates to artic climates, and one of the challenges with passive treatment systems is the cold winter conditions. Anaerobic treatment systems have been built at Kongens Mine near Røros, at Folldal mines, and at Titania's tailings impoundment near Storgangen Mine. These systems utilize sulfate-reducing bacteria that result in the precipitation of metal sulfides. A full- and pilot-scale system at Kongens Mine and Folldal were built in 2006 to remove copper and zinc from typical ARD in an alpine climate. Previous testing with pilot scale systems at Kongens Mine showed that up to 85% copper and 48% zinc could be removed. At Titania A/S the anaerobic system is designed to remove nickel from neutral waters. At this system over 90% nickel is removed when water flow is regulated at a constant flow. Testing shows that the system can function in cold winter conditions, however, optimal metal removal is achieved under warmer temperatures. Temperatures changes by global climatic warming will not adversely affect these anaerobic systems. However, extreme precipitation events and the resulting rapid fluctuations of ARD runoff will provide a challenge for the effectiveness of these systems.
|
Emerick, J. C., Wildeman, T. R., Cohen, R. R., & Klusman, R. W. (1994). Constructed wetland treatment of acid mine discharge at Idaho Springs, Colorado Guidebook on the geology, history, and surface-water contamination and remediation in the area from Denver to Idaho Springs, Colorado (R. C. Severson, Ed.) (Vol. C 1097).
|