|
Kuyucak, N. (1998). Mining, the Environment and the Treatment of Mine Effluents. Int. J. Environ. Pollut., 10(2), 315–325.
Abstract: The environmental impact of mining on the ecosystem, including land, water and air, has become an unavoidable reality. Guidelines and regulations have been promulgated to protect the environment throughout mining activities from start-up to site decommissioning. In particular, the occurrence of acid mine drainage (AMD), due to oxidation of sulfide mineral wastes, has become the major area of concern to many mining industries during operations and after site decommissioning. AMD is characterized by high acidity and a high concentration of sulfates and dissolved metals. If it cannot be prevented or controlled, it must be treated to eliminate acidity, and reduce heavy metals and suspended solids before release to the environment. This paper discusses conventional and new methods used for the treatment of mine effluents, in particular the treatment of AMD.
|
|
|
Kleinmann, R. L. P. (1990). Acid Mine Water Treatment using Engineered Wetlands. Int. J. Mine Water, 9(1-4), 269–276.
Abstract: 400 systems installed within 4 years During the last two decades, the United States mining industry has greatly increased the amount it spends on pollution control. The application of biotechnology to mine water can reduce the industry's water treatment costs (estimated at over a million dollars a day) and improve water quality in streams and rivers adversely affected by acidic mine water draining from abandoned mines. Biological treatment of mine waste water is typically conducted in a series of small excavated ponds that resemble, in a superficial way, a small marsh area. The ponds are engineered to first facilitate bacterial oxidation of iron; ideally, the water then flows through a composted organic substrate that supports a population of sulfate-reducing bacteria. The latter process raises the pH. During the past four years, over 400 wetland water treatment systems have been built on mined lands as a result of research by the U.S. Bureau of Mines. In general, mine operators find that the wetlands reduce chemical treatment costs enough to repay the cost of wetland construction in less than a year. Actual rates of iron removal at field sites have been used to develop empirical sizing criteria based on iron loading and pH. If the pH is 6 or above, the wetland area (in2) required is equivalent to the iron. load (grams/day) divided by 10. Theis requirement doubles at a pH of 4 to 5. At a pH below 4, the iron load (grams/day) should be divided by 2 to estimate the area required (in2).
|
|
|
Gusek, J. J. (1995). Passive-treatment of acid rock drainage: what is the potential bottom line? Min. Eng., 47(3), 250–253.
Abstract: Passive-treatment systems that mitigate acid-rock drainage from coal mines have been operating since the mid-1980s. Large systems at metal mines are being contemplated. A typical man-made passive-treatment-system can mimic a natural wetland by employing the same geochemical principles. Passive-treatment systems, however, are engineered to optimize the biogeochemical processes occurring in a natural wetland ecosystem. The passive-treatment methodology holds promise over chemical neutralization because large volumes of sludge are not generated. Metals may be precipitated as oxides, sulfides or carbonates in the passive-treatment system substrate. The key goal of a passive-treatment system is the long-term immobilization of metals in the substrate materials. The passive-treatment technique may not be applicable in all mine-drainage situations. -from Author
|
|
|
Laine, D. M., & Jarvis, A. P. (2003). Design aspects of passive in situ remediation schemes for minign & industrial effluents. Tübinger Geowissenschaftliche Arbeiten, C68, 95–113.
|
|
|
Jarvis, A. P., & Younger, P. L. (2001). Passive treatment of ferruginous mine waters using high surface area media. Water Res., 35(15), 3643–3648.
Abstract: Rapid oxidation and accretion of iron onto high surface area media has been investigated as a potential passive treatment option for ferruginous, net-alkaline minewaters. Two pilot-scale reactors were installed at a site in County Durham, UK. Each 2.0m high cylinder contained different high surface area plastic trickling filter media. Ferruginous minewater was fed downwards over the media at various flow-rates with the objective of establishing the efficiency of iron removal at different loading rates. Residence time of water within the reactors was between 70 and 360s depending on the flow-rate (1 and 12l/min, respectively). Average influent total iron concentration for the duration of these experiments was 1.43mg/l (range 1.08-1.84mg/l; n=16), whilst effluent iron concentrations averaged 0.41mg/l (range 0.20-1.04mg/l; n=15) for Reactor A and 0.38mg/l (range 0.11-0.93mg/l; n=16) for Reactor B. There is a strong correlation between influent iron load and iron removal rate. Even at the highest loading rates (approximately 31.6g/day) 43% and 49% of the total iron load was removed in Reactors A and B, respectively. At low manganese loading rates (approximately 0.50-0.90g/day) over 50% of the manganese was removed in Reactor B. Iron removal rate (g/m3/d) increases linearly with loading rate (g/day) up to 14g/d and the slope of the line indicates that a mean of 85% of the iron is removed. In conclusion, it appears that the oxidation and accretion of ochre on high surface area media may be a promising alternative passive technology to constructed wetlands at certain sites.
|
|