Home | << 1 2 3 4 5 >> |
LaPointe, F., Fytas, K., & McConchie, D. (2005). Using permeable reactive barriers for the treatment of acid rock drainage. International journal of surface mining, reclamation and environment, 19(1), 57–65.
Abstract: Acid mine drainage (AMD) is the most serious environmental problem facing the Canadian mineral industry today. It results from oxidation of sulphide minerals (e.g. pyrite or pyrrhotite) contained in mine waste or mine tailings and is characterized by acid effluents rich in heavy metals that are released into the environment. A new acid remediation technology is presented, by which metallurgical residues from the aluminium extraction industry are used to construct permeable reactive barriers (PRBs) to treat acid mine effluents. This technology is very promising for treating acid mine effluents in order to decrease their harmful environmental effects
|
Akcil, A., & Koldas, S. (2006). Acid Mine Drainage (AMD): causes, treatment and case studies. J. Cleaner Prod., 14(12-13), 1139–1145.
Abstract: This paper describes Acid Mine Drainage (AMD) generation and its associated technical issues. As AMD is recognized as one of the more serious environmental problems in the mining industry, its causes, prediction and treatment have become the focus of a number of research initiatives commissioned by governments, the mining industry, universities and research establishments, with additional inputs from the general public and environmental groups. In industry, contamination from AMD is associated with construction, civil engineering mining and quarrying activities. Its environmental impact, however, can be minimized at three basic levels: through primary prevention of the acid-generating process; secondary control, which involves deployment of acid drainage migration prevention measures; and tertiary control, or the collection and treatment of effluent.
|
Kuyucak, N. (2002). Acid mine drainage prevention and control options. CIM Bull., 95(1060), 96–102.
Abstract: Acid mine drainage (AMD) is one of the most significant environmental challenges facing the mining industry worldwide. It occurs as a result of natural oxidation of sulphide minerals contained in mining wastes at operating and closed/decommissioned mine sites. AMD may adversely impact the surface water and groundwater quality and land use due to its typical low pH, high acidity and elevated concentrations of metals and sulphate content. Once it develops at a mine, its control can be difficult and expensive. If generation of AMD cannot be prevented, it must be collected and treated. Treatment of AMD usually costs more than control of AMD and may be required for many years after mining activities have ceased. Therefore, application of appropriate control methods to the site at the early stage of the mining would be beneficial. Although prevention of AMD is the most desirable option, a cost-effective prevention method is not yet available. The most effective method of control is to minimize penetration of air and water through the waste pile using a cover, either wet (water) or dry (soil), which is placed over the waste pile. Despite their high cost, these covers cannot always completely stop the oxidation process and generation of AMD. Application of more than one option might be required. Early diagnosis of the problem, identification of appropriate prevention/control measures and implementation of these methods to the site would reduce the potential risk of AMD generation. AMD prevention/control measures broadly include use of covers, control of the source, migration of AMD, and treatment. This paper provides an overview of AMD prevention and control options applicable for developing, operating and decommissioned mines.
|
Berthelot, D., Haggis, M., Payne, R., McClarty, D., & Courtain, M. (1999). Application of water covers, remote monitoring and data management systems to environmental management at uranium tailings sites in the Serpent River Watershed. CIM Bull., 92(1033), 70–77.
Abstract: Over forty years of uranium mining in the Elliot lake region of Ontario (1956-1996) has resulted in the production of over 300 million pounds of uranium. With the completion of mining activity Rio Algom limited and Denison Mines limited are utilizing progressive environmental technologies and management systems to reduce and manage the environmental risks associated with the 150 million tonnes of potentially acid-generating tailings in nine regional waste management areas. Water covers designed to reduce oxygen entry and, thereby, significantly inhibit acid generation, have been applied at six of the sites with the Quirke site serving as a demonstration site for the Mine Environmental Neutral Drainage program, All five of Rio Algom limited's effluent treatment plants are monitored and controlled from a central control station utilizing a Supervisory Control and Data Acquisition (SCADA) system based on “Fix Dmacs” technology Scheduling, auditing and reporting of plant operating and environmental monitoring programs for the entire watershed are controlled utilizing the Regional Environmental Information Management System (REIMS). Proper application of these technologies and management systems facilitates delivery of cost-effective environmental monitoring, care and maintenance programs at these sites and provides tools to demonstrate compliance with all environmental performance criteria.
|
Nakazawa, H. (2006). Treatment of acid mine drainage containing iron ions and arsenic for utilization of the sludge. Sohn International Symposium Advanced Processing of Metals and Materials, Vol 9, , 373–381.
Abstract: An acid mine drainage in abandoned Horobetsu mine in Hokkaido, Japan, contains arsenic and iron ions; total arsenic ca.10ppm, As(III) ca. 8.5ppm, total iron 379ppm, ferrous iron 266ppm, pH1.8. Arsenic occurs mostly as arsenite (As (III)) or arsenate (As (V)) in natural water. As(III) is more difficult to be remove than As(V), and it is necessary to oxidize As(III) to As(V) for effective removal. 5mL of the mine drainage or its filtrate through the membrane filter (pore size 0.45 mu m) were added to arsenite solutions (pH1.8) with the concentration of 5ppm. After the incubation of 30 days, As(III) was oxidized completely with the addition of the mine drainage while the oxidation did not occur with the addition of filtrate, indicating the microbial oxidation of As(III). In this paper, we have investigated the microbial oxidation of As(III) in acid water below pH2.0.
|