Reisinger, R. W., & Gusek, J. (1999). Mitigation of water contamination at the historic Ferris-Haggarty Mine, Wyoming. Min. Eng., 51(8), 49–53.
Abstract: An historic underground copper mine in Wyoming is discharging neutral but copper-laden water into a pristine creek. The EPA-deferred site qualifies for reclamation by the Wyoming Abandoned Mine Land (AML) program. The cleanup goal is to restore the discharge so that the creek can eventually support a trout fishery. Hydrological and geochemical investigations underground have suggested two sources of mine water: one clean and the other containing copper. Results of bench- and pilot-scale tests support the viability of using low-cost passive treatment techniques to reduce copper concentrations in the near-freezing mine discharge.
|
|
|
Ntengwe, F. W. (2005). An overview of industrial wastewater treatment and analysis as means of preventing pollution of surface and underground water bodies – The case of Nkana Mine in Zambia. Phys. Chem. Earth, 30(11-16 Spec. Iss.), 726–734.
Abstract: The wastewaters coming from mining operations usually have low pH (acidic) values and high levels of metal pollutants depending on the type of metals being extracted. If unchecked, the acidity and metals will have an impact on the surface water. The organisms and plants can adversely be affected and this renders both surface and underground water unsuitable for use by the communities. The installation of a treatment plant that can handle the wastewaters so that pH and levels of pollutants are reduced to acceptable levels provides a solution to the prevention of polluting surface and underground waters and damage to ecosystems both in water and surrounding soils. The samples were collected at five points and analyzed for acidity, total suspended solids, and metals. It was found that the pH fluctuated between pH 2 when neutralization was forgotten and pH 11 when neutralization took place. The levels of metals that could cause impacts to the water ecosystem were found to be high when the pH was low. High levels of metals interfere with multiplication of microorganisms, which help in the natural purification of water in stream and river bodies. The fish and hyacinth placed in water at the two extremes of pH 2 and pH 11 could not survive indicating that wastewaters from mining areas should be adequately treated and neutralized to pH range 6-9 if life in natural waters is to be sustained. < copyright > 2005 Elsevier Ltd. All rights reserved.
|
|
|
Miller, S. D. (1999). Overview of acid mine drainage issues and control strategies Remediation and management of degraded lands. In M. H. Wong, J. W. C. Wong, & A. J. M. Baker (Eds.),. Boca Raton: Lewis Publishers.
|
|
|
LaPointe, F., Fytas, K., & McConchie, D. (2005). Using permeable reactive barriers for the treatment of acid rock drainage. International journal of surface mining, reclamation and environment, 19(1), 57–65.
Abstract: Acid mine drainage (AMD) is the most serious environmental problem facing the Canadian mineral industry today. It results from oxidation of sulphide minerals (e.g. pyrite or pyrrhotite) contained in mine waste or mine tailings and is characterized by acid effluents rich in heavy metals that are released into the environment. A new acid remediation technology is presented, by which metallurgical residues from the aluminium extraction industry are used to construct permeable reactive barriers (PRBs) to treat acid mine effluents. This technology is very promising for treating acid mine effluents in order to decrease their harmful environmental effects
|
|
|
Laine, D. M., & Jarvis, A. P. (2003). Engineering design aspects of passive in situ remediation of mining effluents. Land Contam. Reclam., 11(2), 113–126.
Abstract: Passive treatment of contaminated effluents can offer a 'low cost' management opportunity to remediate drainages to the standards required by enforcement agencies. However, the initial cost of construction of passive treatment systems is significant and often in excess of that for active treatment systems. It is therefore important that the engineering design of the passive systems produces an effective and efficient scheme to enable the construction and maintenance costs to be minimised as far as possible. Possible parameters for the design of passive systems are suggested to seek to obtain uniformity in size and layout of treatment elements where this may be possible. Passive treatment systems include aeration systems, sedimentation ponds, aerobic and anaerobic wetlands, anoxic limestone drains and reducing alkalinity producing systems. Most active treatment systems also include passive elements in the treatment stream. The basic design considerations that should be considered to ensure the construction of efficient systems are discussed.
|
|